Twin-wall insulated flue systems (no chimney)
Supplying and fitting a complete 150 mm twin-wall insulated stainless steel flue system costs €1,800 to €3,400 for the flue alone, or €3,400 to €5,400 packaged with a 5 to 8 kW EcoDesign stove.
Fitting a real wood-burning or multifuel stove in modern Irish extensions, timber-frame builds and bungalows with no masonry stack.
Free, no obligation. One local installer prices it, not five.
- €1,800–€3,400twin-wall flue system, fitted
- €3,400–€5,400stove + twin-wall fitted
- 50–60 mmtypical clearance to timber
- 2 to 3 daystypical on-site fit time

Two ways to route a twin-wall flue in an Irish home
External gable wall route
- How it runs
- 45° or 90° tee exits through the outside wall and rises cleanly up the exterior wall past the eaves
- Visual impact
- Zero loss of upstairs bedroom floor space; powder-coated black or brushed stainless pipe visible outside
- Draw & cooling
- Slightly more exposed to Atlantic wind; keep horizontal runs short and fit anti-downdraught cowl
- Typical flue cost
- €1,800 to €3,000 fitted
Internal straight-up roof route
- How it runs
- Rises vertically from stove through upstairs bedroom/attic (boxed in) and exits through pitched roof slates
- Visual impact
- Nothing visible on external house wall; short boxed-in chase inside upper room
- Draw & cooling
- Warmest flue gas path and strongest natural upward draw with zero bends
- Typical flue cost
- €2,100 to €3,400 fitted (incl. boxing & roof flashing)
Price my stove
Four quick taps show your Irish stove installation figure before we ask for a phone number. One installer rings you, not five.
A twin-wall insulated flue setup, with a twin-wall insulated flue, supplied and fitted: €3,400 to €5,400, typical Irish fitted range.
How this stove figure is worked out
The range reflects typical Irish rates for that appliance type, flue route and scope. Room-heater figures cover an EcoDesign 2022 stove, register plate, vitreous connecting pipe, bird cowl, smoke test and I.S. EN 50291-1 CO alarm. Selecting chimney relining allows for an 8 m to 10 m 904L flexible stainless liner. Boiler stoves allow for open-vented copper primaries and a heat-leak radiator. Tall 3-storey roof scaffolding, core-drilling air vents and marble surrounds depend on the house and are confirmed during the chimney survey.
Part J clearances, roof heights and condensation control
- High-density mineral wool core. Twin-wall pipe sandwiches 25 mm to 30 mm of rockwool insulation between inner 316L/904L and outer stainless skins, cutting combustible clearance to typically 50 mm or 60 mm (check the exact pipe rating).
- Transition before any wall or ceiling. Uninsulated single-wall vitreous stove pipe must switch to twin-wall insulated pipe at least 425 mm below a combustible ceiling or before entering a wall sleeve.
- Roof termination height under Part J. The cowl must finish at least 600 mm above the roof ridge if within 600 mm horizontally of the ridge, or maintain 2,300 mm horizontal clearance from the pitched slope.
- Ventilated firestop plates and boxing. Anywhere twin-wall passes through a timber floor or upstairs bedroom, ventilated firestop spacers and non-combustible boxing prevent accidental contact and preserve air flow.
Related stove & flue guides
Part J rules IrelandAir vents above 5 kW, airtight homes, I.S. EN 50291 CO alarms and ridge heights.
Hearths & clearances125 mm constructional vs 12 mm hearths, front aprons and timber mantel gaps.
Freestanding stoves5 to 8 kW cast-iron and steel wood or multifuel stoves fitted in Irish hearths.
Stove installation costComplete Irish breakdown for room heaters, boiler stoves, liners and extras.
Chimney flue liners316L and 904L flexible stainless liners, vermiculite insulation and chimney cowls.
kW room sizing guideMatching output to room cubic volume (1 kW per 14 m³) so glass stays clean.Stove fitting questions answered
How much does a twin-wall flue cost fitted in Ireland?
A complete 150 mm twin-wall insulated flue supplied and fitted typically runs €1,800 to €3,400 depending on single-storey bungalow versus two-storey ridge height. Paired with a 5 kW stove, budget €3,400 to €5,400.
Do I need planning permission for an external twin-wall chimney flue?
Domestic flues on rear or side elevations up to 1 m above the highest part of the roof are generally treated as minor works, though flues on the front street-facing elevation or on a Protected Structure should be confirmed with your local council first.
Can twin-wall flues be painted black to match gutters and fascia?
Yes. Factory powder-coated matte black twin-wall lengths blend cleanly beside black fascia, soffits and downpipes on Irish rendered walls.
Why is twin-wall pipe dearer than flexible chimney liner?
Every 1 m length is precision-welded double-skinned stainless steel packed with compressed rockwool, paired with locking bands, wall brackets, ventilated firestops and lead or EPDM roof flashings.
Every stove installation page and Part J guide
Stoves & flue systems
Part J, sizing & specs

Check your stove fitting figure before booking a chimney survey
Choose the appliance, flue route and scope. When you are ready for a written survey price, your request goes to a single stove installer in your county.